IME Alliance Electronic Detonators – Safety Alert

First published by MSHA.

Electronic Detonators are NOT the same as Electric Detonators
Electronic and electric detonators may look similar and serve the same function, but they are very different.

Key Differences:
Lead wire attachment – As demonstrated in the figure below, the wire leads of the electronic detonator do not attach directly to a match head or bridge wire, like electric detonators. In the case of electric detonators, the direct connection of the wire leads to the matchhead or bridge wire makes them susceptible to initiation from static, stray current and/or radio frequency (RF) energy, whereas electronic detonators are not.

Added protection – Electronic detonators have other components to increase protection from extraneous energy sources: a spark gap device to protect against static discharge events (high voltage spikes from static build up on personnel, equipment, etc.), the use of current limiting resistors, amongst other devices or design features.

EMP – Both electric and electronic detonators can be damaged by an electromagnetic pulse (EMP). However, electronic detonators generally have built-in protection from this type of extraneous energy.

Pressure induced damage – Both electric and electronic detonators can incorporate dynamic and static pressure resistance, however electronic detonators (which use microchip technology and logic to provide timing and firing control) may have a higher susceptibility to damage.

Enhanced control systems – Electronic Blasting Machines are the only devices designed to provide password protection, programming capability and the energy levels needed to charge the electronic detonators in a circuit and send a fire command.

Interchangeability – Electronic detonating systems are unique and system components must NEVER be interchanged. Users should read and understand all aspects of the system they use and follow the manufacturer’s recommendations. Electric detonators can be used with any appropriate firing device.

Training – ALWAYS consult your manufacturer for proper training information before attempting to operate any Electronic Blasting Initiation System.

diagram of Electronic Detonators, Electronic and electric detonators may look similar and serve the same function, but they are very different.
Best Practices:

ALWAYS clear the blast area of personnel, vehicles, and equipment prior to hooking up to the firing device or blast controller. In addition, the blast area should remain clear until the charge on the electronic detonators have had sufficient time to bleed off.


McCraren Compliance offers many opportunities in safety training to help circumvent accidents. Please take a moment to visit our calendar of classes to see what we can do to help your safety measures from training to consulting.

MSHA: Final rule on electronic detonators in metal and nonmetal mines now in effect

blast-warning-sign
Photo: vale_t/iStockphoto
March 19, 2020

Washington — The Mine Safety and Health Administration’s direct final rule concerning advances in electronic detonators in metal and nonmetal mines has gone into effect, the agency announced March 18.

The agency first defined detonators in its regulations in 1979 as devices “containing a detonating charge that is used to initiate an explosive such as electric blasting caps and nonelectrical instantaneous or delay blasting caps.”

MSHA states it initially believed that definition provided a means for the “automatic inclusion” of new technology. In January 1991, the agency clarified that detonating cords are not included in the definition and divided detonators into two classes.

The final rule adds the words “electronic detonators” to its definitions in 30 CFR 56.6000 and 57.6000. It also includes a waiting period of at least 30 minutes for misfires of electronic detonators, or longer if the manufacturer recommends it (56.6310 and 57.6310). Additionally, electronic detonators are added to circuit testing rules (56.6407 and 57.6407) and for precautions during storms (57.6604).

The agency’s other explosive standards in 30 CFR 56 and 30 CFR 57 (Subparts E) still apply to electronic detonators.

“For those electronic detonator systems that the agency has reviewed, MSHA agrees with [the Institute of Makers of Explosives] that electronic detonators provide a working environment that is as safe or safer for miners compared to non electric and electric detonators because they provide for greater control of a blast,” the final rule states. “MSHA believes that recognizing electronic detonator systems as distinct from electric detonators will eliminate confusion over certain regulatory requirements.”